Source code for nirfmxnr.pvt_results

"""Provides methods to fetch and read the Pvt measurement results."""

import functools

import nirfmxnr.attributes as attributes
import nirfmxnr.enums as enums
import nirfmxnr.errors as errors
import nirfmxnr.internal._helper as _helper


def _raise_if_disposed(f):
    """From https://stackoverflow.com/questions/5929107/decorators-with-parameters."""

    @functools.wraps(f)
    def aux(*xs, **kws):
        meas_obj = xs[0]  # parameter 0 is 'self' which is the measurement object
        if meas_obj._signal_obj.is_disposed:
            raise Exception("Cannot access a disposed NR signal configuration")
        return f(*xs, **kws)

    return aux


[docs] class PvtResults(object): """Provides methods to fetch and read the Pvt measurement results.""" def __init__(self, signal_obj): """Provides methods to fetch and read the Pvt measurement results.""" self._signal_obj = signal_obj self._session_function_lock = signal_obj._session_function_lock self._interpreter = signal_obj._interpreter
[docs] @_raise_if_disposed def get_measurement_status(self, selector_string): r"""Gets the measurement status indicating whether the off power before and after is within the standard defined limit. Use "carrier<*k*>" or "subblock<*n*>" or "subblock<*n*>/carrier<*k*>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to read this attribute. The default value is 0. +--------------+--------------------------------------------+ | Name (Value) | Description | +==============+============================================+ | Fail (0) | Indicates that the measurement has failed. | +--------------+--------------------------------------------+ | Pass (1) | Indicates that the measurement has passed. | +--------------+--------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.PvtMeasurementStatus): Returns the measurement status indicating whether the off power before and after is within the standard defined limit. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.PVT_RESULTS_MEASUREMENT_STATUS.value ) attr_val = enums.PvtMeasurementStatus(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_absolute_off_power_before(self, selector_string): r"""Gets the OFF power in the segment before the captured burst for the uplink direction, while it returns NaN in the segment after the captured burst for the downlink direction. The segment is defined as one slot prior to a short transient segment and the burst. This value is expressed in dBm. Use "carrier<*k*>" or "subblock<*n*>" or "subblock<*n*>/carrier<*k*>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to read this result. The default value is 0. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the OFF power in the segment before the captured burst for the uplink direction, while it returns NaN in the segment after the captured burst for the downlink direction. The segment is defined as one slot prior to a short transient segment and the burst. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.PVT_RESULTS_ABSOLUTE_OFF_POWER_BEFORE.value, ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_absolute_off_power_after(self, selector_string): r"""Gets the OFF power in the segment after the captured burst for the uplink direction, while it returns NaN in the segment after the captured burst for the downlink direction. The segment is defined as one slot after the burst and a short transient segment. This value is expressed in dBm. Use "carrier<*k*>" or "subblock<*n*>" or "subblock<*n*>/carrier<*k*>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to read this result. The default value is 0. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the OFF power in the segment after the captured burst for the uplink direction, while it returns NaN in the segment after the captured burst for the downlink direction. The segment is defined as one slot after the burst and a short transient segment. This value is expressed in dBm. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.PVT_RESULTS_ABSOLUTE_OFF_POWER_AFTER.value, ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_absolute_on_power(self, selector_string): r"""Gets the average ON power within the measurement interval. This value is expressed in dBm. Use "carrier<*k*>" or "subblock<*n*>" or "subblock<*n*>/carrier<*k*>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to read this result. The default value is 0. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the average ON power within the measurement interval. This value is expressed in dBm. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.PVT_RESULTS_ABSOLUTE_ON_POWER.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_burst_width(self, selector_string): r"""Gets the width of the captured burst for the uplink direction, while it returns NaN of the captured burst for the downlink direction. This value is expressed in seconds. Use "carrier<*k*>" or "subblock<*n*>" or "subblock<*n*>/carrier<*k*>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to read this result. The default value is 0. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the width of the captured burst for the uplink direction, while it returns NaN of the captured burst for the downlink direction. This value is expressed in seconds. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.PVT_RESULTS_BURST_WIDTH.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_peak_windowed_off_power(self, selector_string): r"""Gets the NaN for the uplink direction, while it returns the peak power value of 70/N us windowed power during all OFF regions in the measurement interval. This value is expressed in dBm/MHz. Use "carrier<*k*>" or "subblock<*n*>" or "subblock<*n*>/carrier<*k*>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to read this result. The default value is 0. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the NaN for the uplink direction, while it returns the peak power value of 70/N us windowed power during all OFF regions in the measurement interval. This value is expressed in dBm/MHz. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.PVT_RESULTS_PEAK_WINDOWED_OFF_POWER.value, ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_peak_windowed_off_power_margin(self, selector_string): r"""Gets the NaN for the uplink direction, while it returns the :py:attr:`~nirfmxnr.attributes.AttributeID.PVT_RESULTS_PEAK_WINDOWED_OFF_POWER` to the 3GPP limit. This value is expressed in dB. Use "carrier<*k*>" or "subblock<*n*>" or "subblock<*n*>/carrier<*k*>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to read this result. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the NaN for the uplink direction, while it returns the :py:attr:`~nirfmxnr.attributes.AttributeID.PVT_RESULTS_PEAK_WINDOWED_OFF_POWER` to the 3GPP limit. This value is expressed in dB. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.PVT_RESULTS_PEAK_WINDOWED_OFF_POWER_MARGIN.value, ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_peak_windowed_off_power_time(self, selector_string): r"""Gets the NaN for the uplink direction, while it returns the time offset of the :py:attr:`~nirfmxnr.attributes.AttributeID.PVT_RESULTS_PEAK_WINDOWED_OFF_POWER`. This value is expressed in seconds. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the NaN for the uplink direction, while it returns the time offset of the :py:attr:`~nirfmxnr.attributes.AttributeID.PVT_RESULTS_PEAK_WINDOWED_OFF_POWER`. This value is expressed in seconds. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.PVT_RESULTS_PEAK_WINDOWED_OFF_POWER_TIME.value, ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def fetch_measurement_array(self, selector_string, timeout): r"""Fetches an array of PVT ON and OFF powers along with measurement status and burst width. Use "subblock<*n*>" as the selector string to read results from this method. Args: selector_string (string): This parameter specifies a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of result name, and subblock number. Example: "subblock0" "result::r1/subblock0" You can use the :py:meth:`build_subblock_string` method to build the selector string. timeout (float): This parameter specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete. The default value is 10. Returns: Tuple (measurement_status, absolute_off_power_before, absolute_off_power_after, absolute_on_power, burst_width, error_code): measurement_status (enums.PvtMeasurementStatus): This parameter returns the measurement status indicating whether the off power before and after is within the standard defined limit. +--------------+--------------------------------------------+ | Name (Value) | Description | +==============+============================================+ | Fail (0) | Indicates that the measurement has failed. | +--------------+--------------------------------------------+ | Pass (1) | Indicates that the measurement has passed. | +--------------+--------------------------------------------+ absolute_off_power_before (float): This parameter returns the OFF power in the segment before the captured burst. The segment is defined as one slot prior to a short transient segment and the burst. This value is expressed in dBm. absolute_off_power_after (float): This parameter returns the OFF power in the segment after the captured burst. The segment is defined as one slot after the burst and a short transient segment. This value is expressed in dBm. absolute_on_power (float): This parameter returns the power of the subframes within the captured burst. This value is expressed in dBm. burst_width (float): This parameter returns the width of the captured burst. This value is expressed in seconds. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) ( measurement_status, absolute_off_power_before, absolute_off_power_after, absolute_on_power, burst_width, error_code, ) = self._interpreter.pvt_fetch_measurement_array(updated_selector_string, timeout) finally: self._session_function_lock.exit_read_lock() return ( measurement_status, absolute_off_power_before, absolute_off_power_after, absolute_on_power, burst_width, error_code, )
[docs] @_raise_if_disposed def fetch_measurement(self, selector_string, timeout): r"""Fetches PVT ON and OFF powers along with measurement status and burst width. Use "carrier<*k*>" or "subblock<*n*>/carrier<*k*>" as the selector string to read from this method. Args: selector_string (string): This parameter specifies a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of result name, subblock number, and carrier number. Example: "subblock0/carrier0" "result::r1/subblock0/carrier0" You can use the :py:meth:`build_carrier_string` method to build the selector string. timeout (float): This parameter specifies the timeout for which the method waits for the measurement to complete. This value is expressed in seconds. A value of -1 specifies that the method waits until the measurement is complete. Returns: Tuple (measurement_status, absolute_off_power_before, absolute_off_power_after, absolute_on_power, burst_width, error_code): measurement_status (enums.PvtMeasurementStatus): This parameter returns the measurement status indicating whether the off power before and after is within the standard defined limit. +--------------+--------------------------------------------+ | Name (Value) | Description | +==============+============================================+ | Fail (0) | Indicates that the measurement has failed. | +--------------+--------------------------------------------+ | Pass (1) | Indicates that the measurement has passed. | +--------------+--------------------------------------------+ absolute_off_power_before (float): This parameter returns the OFF power in the segment before the captured burst. The segment is defined as one slot prior to a short transient segment and the burst. This value is expressed in dBm. absolute_off_power_after (float): This parameter returns the OFF power in the segment after the captured burst. The segment is defined as one slot after the burst and a short transient segment. This value is expressed in dBm. absolute_on_power (float): This parameter returns the power of the subframes within the captured burst. This value is expressed in dBm. burst_width (float): This parameter returns the width of the captured burst. This value is expressed in seconds. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) ( measurement_status, absolute_off_power_before, absolute_off_power_after, absolute_on_power, burst_width, error_code, ) = self._interpreter.pvt_fetch_measurement(updated_selector_string, timeout) finally: self._session_function_lock.exit_read_lock() return ( measurement_status, absolute_off_power_before, absolute_off_power_after, absolute_on_power, burst_width, error_code, )
[docs] @_raise_if_disposed def fetch_signal_power_trace(self, selector_string, timeout, signal_power, absolute_limit): r"""Fetches an instantanous signal power trace along with the absolute limit for each segment in the trace. For uplink, the power unit of the returned traces is dBm, while for downlink, the power unit of the returned traces is dBm/MHz. Use "carrier<*k*>" or "subblock<*n*>/carrier<*k*>" as the selector string to read this result. Args: selector_string (string): This parameter specifies a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of result name, subblock number, and carrier number. Example: "subblock0/carrier0" "result::r1/subblock0/carrier0" You can use the :py:meth:`build_carrier_string` method to build the selector string. timeout (float): This parameter specifies the timeout for which the method waits for the measurement to complete. This value is expressed in seconds. A value of -1 specifies that the method waits until the measurement is complete. signal_power (numpy.float32): This parameter returns the instantaneous signal power trace. This value is expressed in dBm. absolute_limit (numpy.float32): This parameter returns the instantaneous signal power trace. This value is expressed in dBm. Returns: Tuple (x0, dx, error_code): x0 (float): This parameter returns start time of the signal. This value is expressed in seconds. dx (float): This parameter returns the time bin spacing. This value is expressed in seconds. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) x0, dx, error_code = self._interpreter.pvt_fetch_signal_power_trace( updated_selector_string, timeout, signal_power, absolute_limit ) finally: self._session_function_lock.exit_read_lock() return x0, dx, error_code
[docs] @_raise_if_disposed def fetch_windowed_signal_power_trace(self, selector_string, timeout, windowed_signal_power): r"""Fetches the 70/N us windowed power trace in dBm/MHz for Downlink, while an empty trace is returned for Uplink. Use "carrier<*k*>" or "subblock<*n*>/carrier<*k*>" as the selector string to read this result. Args: selector_string (string): This parameter specifies a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of result name, subblock number, and carrier number. Example: "subblock0/carrier0" "result::r1/subblock0/carrier0" You can use the :py:meth:`build_carrier_string` method to build the selector string. timeout (float): This parameter specifies the timeout for which the method waits for the measurement to complete. This value is expressed in seconds. A value of -1 specifies that the method waits until the measurement is complete. windowed_signal_power (numpy.float32): This parameter returns the 70/N us windowed power trace in dBm/MHz for Downlink, while an empty trace is returned for Uplink. Returns: Tuple (x0, dx, error_code): x0 (float): This parameter returns start time of the signal. This value is expressed in seconds. dx (float): This parameter returns the time bin spacing. This value is expressed in seconds. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) x0, dx, error_code = self._interpreter.pvt_fetch_windowed_signal_power_trace( updated_selector_string, timeout, windowed_signal_power ) finally: self._session_function_lock.exit_read_lock() return x0, dx, error_code